Effective Method to Reduce Circulating Pressures in A Pressurized Mud Cap Drilling System: A Case History of Friction Reducer in Circulating Fluid

Nishanth Samuel,Kyle Dewbre,Charlie Landis
DOI: https://doi.org/10.2118/201377-ms
2020-10-19
Abstract:Abstract An application for Pressurized Mud Cap Drilling (PMCD) was needed to successfully drill an U.S. onshore, unconventional, High Pressure / High Temperature (HP/HT) well. The length of the lateral, highly fractured formation & extremely high MWs needed to drill the lateral proved that conventional drilling methods would not be effective, so PMCD was utilized. The main challenge was to keep circulating pressures low while injecting the circulating fluid into the naturally highly pressurized formation. PMCD involves injecting / losing the circulating fluid (water) into the formation, in this situation, high formation fracture pressures required high surface injection pressures to push the fluid & cuttings into the formation. When the injection pressure was combined with the frictional losses through the drill string, anticipated surface pressures were over 10k psi when circulating. To combat the high circulating pressure, an approach was taken to use Friction Reducer (FR) in the circulating fluid, water, thus reducing the frictional pressure loss while circulating within manageable constraints. This paper will go into detail of the different phases taken to determine the appropriate type of FR based on lab testing, hydraulics model, temperature modeling, and the results from the application of the product in the drilled well. Extensive hydraulics modeling was conducted to determine the feasibility of using the FR and the final anticipated circulating pressure. The BHA and drill string design was optimized to maximize the least amount of pressure drop across the tools while staying within operating parameters. Concerns of the use of FR such as ECD effect, fluid flow characteristics for hole cleaning in the annulus, temperature effects of the water being pumped, and effects in the BHA were all considered in the engineering process. FR testing including, lab testing of the base fluid (water), differential scanning calorimeter to determine effects of BHT, FR shear testing, FR concentration percentage at various flow rates in a flow loop to calculate Reynolds number at the respective flow rates & concentration and differential pressure testing with time and temperatures. Based on the results from the hydraulics modeling and lab tests, an FR was selected and fully utilized in the application of the product. PMCD techniques with this FR was used and was fully successful in the intended reduction of the surface circulating pressures while drilling the well. Surface and downhole results captured the effects of the FR in the fluid system and data was collected and analyzed to show the expected vs actual results on various drilling parameters.
What problem does this paper attempt to address?