Study on the Model Test of the Antibreaking Effect of Fiber Reinforced Concrete Lining in Tunnel

Guang-yao Cui,Xue-lai Wang,Dao-yuan Wang
DOI: https://doi.org/10.1155/2020/5419650
IF: 1.616
2020-10-14
Shock and Vibration
Abstract:In order to study the antibreaking effect of the fiber reinforced concrete lining in the tunnel, this paper takes the a subway tunnel engineering project in F2-3 section of Jiujiawan fault as the research background and carries out the antibreaking model test of the fiber reinforced concrete lining in the active fault zone of high earthquake intensity. The results show that the antibreaking effect of the principle stress and the longitudinal strain of the fiber reinforced concrete lining are 30%∼40% and 80%∼90%, respectively, and the minimum value of the structural safety factor is increased by 4∼5 times. The antibreaking effect of hybrid fiber reinforced concrete lining is better than that of steel fiber reinforced concrete lining. The safety of steel polypropylene hybrid fiber reinforced concrete tunnel lining is the highest, and its minimum structural safety factor is 1.62. In the aspect of improving the antibreaking effect of the tunnel, the toughening effect of fiber reinforced concrete is stronger than that of reinforcing. The research results are of great significance to improve the antibreaking effect of tunnels in active fault areas with high earthquake intensity.
engineering, mechanical,mechanics,acoustics
What problem does this paper attempt to address?