Label‐free high frame rate imaging of circulating blood clots using a dual modal ultrasound and photoacoustic system

Dhiman Das,Kathyayini Sivasubramanian,Praveenbalaji Rajendran,Manojit Pramanik
DOI: https://doi.org/10.1002/jbio.202000371
IF: 3.3899
2020-12-02
Journal of Biophotonics
Abstract:<p>Deep vein thrombosis (DVT) is a disorder when a blood clot (thrombus) is formed in one of the deep veins. These clots detach from the original sites and circulate in the blood stream at high velocities. Diagnosing these blood clots at an early stage is necessary to decide the treatment strategy. For label‐free, in viv<i>o,</i> and real‐time detection, high framerate photoacoustic imaging can be used. In this work, a dual modal clinical ultrasound and photoacoustic (PA) system is used for the high framerate PA imaging of circulating blood clots in blood at linear velocities up to 107 cm/sec. Blood clot had 1.4 times higher signal‐to‐noise ratio (SNR) in the static mode and 1.3 times higher SNR compared to blood PA signal in the flow experiments. This work demonstrates that fast‐moving circulating blood clots are easy to recognize against the background PA signal and may aid in early diagnosis.</p>
optics,biochemical research methods,biophysics
What problem does this paper attempt to address?
The main problem that this paper attempts to solve is to develop a method capable of achieving high - frame - rate label - free imaging of circulating blood clots to assist in the early diagnosis of deep vein thrombosis (DVT). Specifically, the researchers designed a device that combines an ultrasound (US) and a photoacoustic (PA) imaging system for high - frame - rate photoacoustic imaging of blood clots flowing in blood at a speed of up to 107 cm/s. This method can provide a higher signal - to - noise ratio (SNR) than existing imaging techniques, making it easier to identify rapidly - moving blood clots and contributing to the early detection of diseases and the formulation of treatment strategies. ### Main Contribution Points: 1. **High - Frame - Rate Imaging**: By using a pulsed laser diode (PLD) as an excitation source, photoacoustic imaging of up to 7000 frames per second has been achieved, which is crucial for capturing high - speed flowing blood clots. 2. **Label - Free Imaging**: This method does not require the use of any exogenous contrast agents and can directly image clots in the blood, reducing the risk and discomfort to patients. 3. **High Signal - to - Noise Ratio**: In static experiments, the signal - to - noise ratio (SNR) of blood clots is 1.4 times higher than that of the blood background signal; in flow experiments, this ratio is 1.3 times, which makes blood clots easy to identify in the background signal. 4. **Clinical Application Potential**: This system has high potential for clinical translation and may be used for the early diagnosis and management of diseases such as DVT in the future. ### Research Background: - **Deep Vein Thrombosis (DVT)**: DVT is a serious disease that occurs when blood clots form in deep veins. These clots may break off and travel with the blood to the lungs, resulting in pulmonary embolism (PE), which is a life - threatening condition. - **Limitations of Existing Imaging Techniques**: Currently commonly used imaging techniques such as Doppler ultrasound, CT, MRI, etc., although effective, have some limitations, such as being unable to provide information on the composition of blood clots, requiring the use of contrast agents or radiation, etc. - **Advantages of Photoacoustic Imaging**: Photoacoustic imaging combines the high contrast of optical imaging and the high spatial resolution of ultrasound imaging, can image in deeper tissues, and is non - invasive, suitable for frequent examinations. ### Experimental Methods: - **Imaging System**: A clinical system that combines ultrasound and photoacoustic imaging was used, and the photoacoustic imaging part used a pulsed laser diode (PLD) as an excitation source. - **Sample Preparation**: Blood clots in pig blood were prepared and mixed with diluted blood and then injected into a low - density polyethylene (LDPE) tube to simulate blood circulation. - **Flow Rate Control**: By adjusting the settings of the injection pump, experiments with different flow rates were achieved, with the highest flow rate reaching 107 cm/s. ### Results: - **Static Imaging**: Under static conditions, the photoacoustic signal of blood clots is significantly higher than that of the background blood signal, and the signal - to - noise ratio is increased by 1.4 times. - **Dynamic Imaging**: In flow experiments, even under high - speed flow conditions, the photoacoustic signal of blood clots is still significantly higher than that of the background blood signal, and the signal - to - noise ratio is increased by 1.3 times. - **Safety**: The laser energy used in the experiment is within the maximum permissible exposure (MPE) range, ensuring the safety of the experiment. ### Conclusion: This study demonstrates the feasibility of using high - frame - rate photoacoustic imaging technology to detect rapidly - moving blood clots in real - time in the blood. This label - free imaging method has a high signal - to - noise ratio and can effectively identify clots in the blood, providing a new tool for the early diagnosis of diseases such as DVT. Future research will further verify the in - vivo application effect of this technology and promote its clinical translation.