Occlusion tool software for pulmonary vein occlusion verification in atrial fibrillation cryoballoon ablation

Filippo Maria Cauti,Francesco Solimene,Giuseppe Stabile,Marco Polselli,Vincenzo Schillaci,Alberto Arestia,Gergana Shopova,Luigi Iaia,Carlo Maria Giannitti,Pietro Rossi,Stefano Bianchi
DOI: https://doi.org/10.1111/pace.14130
2020-12-01
Pacing and Clinical Electrophysiology
Abstract:<section class="article-section__content"><h3 class="article-section__sub-title section1"> Background</h3><p>Optimal pulmonary vein (PV) occlusion, usually verified with selective contrast injection, is mandatory to obtain an effective PV isolation during cryoballoon (CB) ablation.</p></section><section class="article-section__content"><h3 class="article-section__sub-title section1"> Aim of the study</h3><p>The purpose of this study was to verify the feasibility and the accuracy of a new dielectric sensing system in assessing PV occlusion during CB ablation in patients with atrial fibrillation (AF).</p></section><section class="article-section__content"><h3 class="article-section__sub-title section1"> Methods</h3><p>We enrolled 28 consecutive patients with paroxysmal or persistent AF. After transseptal access, a detailed image reconstruction of left atrium and PVs was achieved with an octapolar or decapolar mapping catheter (Achieve catheter, Medtronic Inc.) and KODEX‐EPD system (EPD Solutions, a Philips company). The degree of PV occlusion with the inflated Arctic Front Advance Cryo‐balloon (Medtronic Inc.) was verified using the new "Occlusion Tool" software module (EPD Solutions, a Philips company) and compared to an angiogram obtained with contrast medium injection in each PV.</p></section><section class="article-section__content"><h3 class="article-section__sub-title section1"> Results</h3><p>A total of 105 PV cryoballoon occlusion were tested. The new Occlusion Tool software module showed a 91% sensitivity and 76% specificity in assessing a complete PV occlusion verified with contrast medium injection. The positive predictive value was 80% and the negative predictive value was 88.6%. Mean procedure time was 81 min ± 17. Mean fluoroscopy time was 6 min ± 2. No 30 days complications were observed.</p></section><section class="article-section__content"><h3 class="article-section__sub-title section1"> Conclusion</h3><p>The new dielectric imaging system was able to assess the degree of PV occlusion during a CB ablation with good sensitivity and specificity.</p><p>This article is protected by copyright. All rights reserved</p></section>
engineering, biomedical,cardiac & cardiovascular systems
What problem does this paper attempt to address?