Supervisory control configurations design for nitrogen and phosphorus removal in wastewater treatment plants

Abdul Gaffar Sheik,Murali Mohan Seepana,Seshagiri Rao Ambati
DOI: https://doi.org/10.1002/wer.1512
2021-02-07
Water Environment Research
Abstract:Model predictive control (MPC) and Fuzzy controllers are designed in a two‐level hierarchical supervisory control framework for control of activated sludge‐based wastewater treatment plants (WWTP) in order to efficiently remove nitrogen and phosphorus. Benchmark simulation model No.3 with a bio‐phosphorus (ASM3bioP) module is used as a working platform. The hierarchical control framework is used to alter the dissolved oxygen in the seventh reactor (DO7) to control ammonia. Lower level PI, MPC, and Fuzzy are used to control the nitrate levels in the fourth reactor (SNO4) by manipulating internal recycle (Qintr) and DO7 in the seventh tank by manipulating mass transfer coefficient (KLa7). MPC and Fuzzy are designed in the supervisory layer to alter the DO7 set‐point based on the ammonia composition in the seventh reactor (NH7). From the analysis, it is observed that the effluent quality is improved with a decrease in ammonia, TN, TP. Though a little difference was observed in the cost for all the control strategies, a trade‐off is maintained between cost and percentage improvement of effluent quality. MPC‐MPC combination showed significant removal in ammonia and better effluent quality when compared to other control strategies.
environmental sciences,engineering, environmental,water resources,limnology
What problem does this paper attempt to address?