Mechanism of Magnetic Permeability Perturbation in Magnetizing-Based Eddy Current Nondestructive Testing

Zhiyang Deng,Zhiheng Yu,Zhongyu Yuan,Xiaochun Song,Yihua Kang
DOI: https://doi.org/10.3390/s22072503
IF: 3.9
2022-03-25
Sensors
Abstract:DC magnetization is generally considered to suppress the usual local magnetic permeability variation and increase the penetration depth for magnetizing-based eddy current testing (MB-ECT) of ferromagnetic materials. In fact, such simple explanations lead to rough nondestructive evaluation and cause new neglected non-uniform magnetic characteristics. Hence, the “perturbation” of the internal magnetic field variation is analyzed using a magnetic dipole model and the mechanism of magnetic permeability perturbation in MB-ECT is revealed. The theoretical analysis and simulations show that a significant permeability perturbation always appears around a defect and presents opposite features with strong and weak magnetization. Furthermore, experimental results indicate that the hidden signal component arising from the local permeability perturbation is critical for both far-side surface and near-side surface defects in the MB-ECT method.
engineering, electrical & electronic,chemistry, analytical,instruments & instrumentation
What problem does this paper attempt to address?