Filling Ratio Optimization for High-Performance Nanoengineered Copper-Water Heat Pipes

Ahmed A. Abdulshaheed,Pengtao Wang,Guanghan Huang,Yueyang Zhao,Chen Li
DOI: https://doi.org/10.1115/1.4050225
2021-03-30
Journal of Thermal Science and Engineering Applications
Abstract:Abstract This experimental test investigates the effect of filling ratio (FR) and inclination angle on the thermal performance of a nanoengineered copper-water heat pipe. A hydrophilic copper oxide coating (CuO) is synthesized and integrated on the inner wall of the evaporation section of the heat pipe. The heat pipe is fabricated from an inner grooved copper pipe with dimensions of 12.7 mm outer diameter, 11 mm inner diameter, and 440 mm length. Ultra-filtered de-ionized (DI) water is used as a working fluid. Four different FRs of DI water 3%, 5%, 10%, and 15% are investigated to determine the optimum configuration. All samples are tested at various inclination angles and working loads. Experimental results show that the optimum filling ratio is the 5% FR, which was indicated by the lowest thermal resistance of 0.019 K/W.
engineering, mechanical,thermodynamics
What problem does this paper attempt to address?