Cathodic protection of UNS C71500 heat exchanger tubes in sulphide polluted Arabian Gulf sea water

J.A. Carew,A. Al-Hashem,A. Al-Sayegh
DOI: https://doi.org/10.1179/000705900101501128
2000-02-01
British Corrosion Journal
Abstract:A laboratory investigation using a specially designed circulating test rig has been undertaken to study the feasibility of achieving complete cathodic protection of UNS C71500 heat exchanger tubes in sea water applications by means of sacrificial carbon steel anodes. The results have indicated that the galvanic current distribution covered the entire 6 m length of the tube. However, the presence of sulphide ions as pollutants in the sea water shifted the galvanic potentials of the tubes to less active potentials and affected the development of the protective films that normally form.
What problem does this paper attempt to address?