Development of Sectored External Pipeline Inspection Gauge for Health Monitoring of Industrial Carbon Steel Pipelines

Shilpi Saha,Debmalya Mukherjee,Y. Chandra,S. C. Ramrane,S. K. Lahiri,P. P. Marathe
DOI: https://doi.org/10.1007/978-981-16-0186-6_9
2021-01-01
Lecture Notes in Mechanical Engineering
Abstract:Magnetic Flux Leakage (MFL)-based inspection gauges are widely used for full periphery inspection under Non-Destructive Testing (NDT) of buried petroleum pipelines. These tools, known as Instrumented Pipeline Inspection Gauge (IPIG), are inserted into the pipeline; it travels along with the cargo and is retrieved at receiving barrel after travelling hundreds of kilometres. However, there are unpiggable pipelines in oil refineries, process industries and power plants (conventional and nuclear), where inline inspection is not possible. These lines are mostly inspected at few locations during in-service inspection schedule by spot thickness measurement, but full-length inspection with full periphery coverage is not feasible due to unavailability of any standard inspection tool. Nevertheless, integrity management of such pipes are of paramount importance. To address this challenge, a novel inspection tool called Sectored External PIG for 10″ NB carbon steel pipeline (SEPIG-10) has been developed based on MFL technology. The tool is extremely light weight and can be moved across the pipe (axially and circumferentially) with ease. The tool has been successfully tested at static test rigs with known calibration defects, giving encouraging results in defect detection and size (length, width and depth) estimation.
What problem does this paper attempt to address?