Water content quantification by FTIR in carboxymethyl cellulose food additive

Marco Consumi,Gemma Leone,Gabriella Tamasi,Agnese Magnani
DOI: https://doi.org/10.1080/19440049.2021.1948619
2021-07-13
Abstract:<span>Water content quantification of raw polysaccharide materials for food processing is generally performed by gravimetric analysis or titrimetric methods, which are time- and energy-consuming, non-eco-friendly and sample destructive. The present study develops and validates a new approach, based on the use of Fourier transform infrared (FTIR) spectroscopy, resulting in a model of the water content of carboxymethyl cellulose (CMC) polysaccharides. Samples of CMC were exposed to different relative humidity conditions. Water content was determined by standard gravimetric methods (OIV-Oeno 404–2010) and compared with the area of FTIR absorption in the range 3675–2980 cm<sup>−1</sup>, attributed to the stretching of OH groups. The strong correlation between gravimetric results and FTIR area (R<sup>2</sup> = 0.88) showed no signs of bias across the water content range. A cross-validation technique to predict the water content by band area was assessed obtaining a general equation: y = 2.12 x + 2.80 with a high repetitively and good prediction of the tested models.</span>
What problem does this paper attempt to address?