Effects of change in intraocular pressure on axial eye length and lens position

C Leydolt,O Findl,W Drexler
DOI: https://doi.org/10.1038/sj.eye.6702709
IF: 4.4563
2007-01-19
Eye
Abstract:PurposeTo quantify the biometric changes of ocular dimensions with mechanical elevation of intraocular pressure (IOP) in vivo, to get a better understanding of the elastic properties of the human ocular structures that may play a role in the pathogenesis of various diseases such as myopia or glaucoma.MethodsChanges in IOP were induced by a suction cup in 18 eyes under cycloplegia. Axial eye length (AEL) and anterior chamber depth (ACD) were measured with non-invasive laser interferometry during elevation of the IOP 10 and 20 mmHg over baseline values and after a 10-min resting period.ResultsIOP elevation of 10 and 20 mmHg respectively caused a significant increase of AEL of 23 μm (95% confidence interval: 14–34 μm) and 39 μm (confidence interval (CI): 28–51 μm). After mechanical oculopression, which resulted in an IOP reduction of –5.1 mmHg (CI: −6.3 to −4.0 mmHg) vsbaseline, a significant shortening of −7 μm (CI: −13 to 0 μm) was observed. The change in AEL correlated with the change in IOP (r=0.66, P=0.005). Furthermore, a significant increase in ACD of 30 μm (CI: 24–36 μm) was detected with IOP reduction after oculopression, but no change was seen during IOP elevation.ConclusionsBiometric changes of the human eye as a response to IOP changes were assessed in vivo. The correlation between change in AEL and IOP found emphasizes the need of in vivoocular rigidity measurements in the human eye.
ophthalmology
What problem does this paper attempt to address?