Reappraisal of Peak Shape Method Based on Average Geometrical Symmetry Factor and Its Application to Thermoluminescence Glow Curves

Mohan Kundu,Saurish Chakrabarty,Sukhamoy Bhattacharyya,Partha Sarathi Majumdar
DOI: https://doi.org/10.1002/pssb.202100277
2021-09-24
physica status solidi (b)
Abstract:A new set of peak shape formulas at different fractional intensities is proposed to extract the activation energy from a thermoluminescence (TL) glow curve. The peak shape coefficients are formulated on the basis of average geometrical symmetry factor which is estimated considering its dependence on the relevant TL parameters. An empirical dependence of geometrical symmetry factor on order of kinetics and other parameters has also been reported. The present method is employed on TL peaks generated in General Order Kinetics (GOK) approximation and in One Trap One Recombination centre (OTOR) model using a wide range of TL parameters. During the course of TL peak simulation, an alternative analytical approach to evaluate the 'temperature integral' is developed. The present method seems to be useful to evaluate activation energy for all peaks except for the heavy retrapping cases when the initial trap saturation is considerably high. Probable reason behind this limitation has also been explored by examining the correspondence between the temperature average of order of kinetics and the retrapping to recombination probability. Finally, the new peak shape formulas are tried on isolated single peaks deconvoluted from composite experimental TL curves reported in the literature and the results are quite satisfactory.This article is protected by copyright. All rights reserved.
What problem does this paper attempt to address?