VUV Intensity Measurement of a 172 nm Xe Excimer Lamp by means of Oxygen Actinometry

Zs László,I. Ilisz,G. Peintler,A. Dombi
DOI: https://doi.org/10.1080/01919519809480350
1998-01-01
Ozone: Science and Engineering
Abstract:The light power of a xenon excimer VUV source was determined by means of oxygen actinometiy. It was found that the method is not applicable for direct measurement of the light power mainly because of the side-reactions of ozone with oxygen atoms. Model calculations led to a simple equation between the quantum yield and the concentrations of ozone and oxygen. The correlation between the overall quantum yield and the ozone and oxygen concentration at room temperature is Φ = 2 - 1.l0[O3]/(O2]1.94, and at atmospheric oxygen pressure Φ = 2 - 520 [O3].