A novel technique for placement of aorto-ostial coronary stent using goose-neck snare

Prashant Ramdas Wankhade,Abhilash TP. Nair,S.S. Binu
DOI: https://doi.org/10.1016/j.ihjccr.2021.10.004
2021-09-01
IHJ Cardiovascular Case Reports (CVCR)
Abstract:During aorto-ostial stenting, many times we miss the ostium, and other times the stent protrudes into the aorta. This novel technique for aorto-ostial stent placement using goose-neck snare gives a fair idea about the location and 3-dimensional anatomy of coronary ostium using a 2-dimensional fluoroscopy system and seems reliable.
What problem does this paper attempt to address?