Effects of bipolar irreversible electroporation with different pulse durations in a prostate cancer mouse model

Song Hee Kim,Jeon Min Kang,Yubeen Park,Yunlim Kim,Bumjin Lim,Jung-Hoon Park
DOI: https://doi.org/10.1038/s41598-024-60413-y
IF: 4.6
2024-05-02
Scientific Reports
Abstract:Irreversible electroporation (IRE) is a non-thermal ablation technique for local tumor treatment known to be influenced by pulse duration and voltage settings, affecting its efficacy. This study aims to investigate the effects of bipolar IRE with different pulse durations in a prostate cancer mouse model. The therapeutic effectiveness was assessed with in vitro cell experiments, in vivo tumor volume changes with magnetic resonance imaging, and gross and histological analysis in a mouse model. The tumor volume continuously decreased over time in all IRE-treated groups. The tumor volume changes, necroptosis (%), necrosis (%), the degree of TUNEL-positive cell expression, and ROS1-positive cell (%) in the long pulse duration-treated groups (300 μs) were significantly increased compared to the short pulse duration-treated groups (100 μs) (all p < 0.001). The bipolar IRE with a relatively long pulse duration at the same voltage significantly increased IRE-induced cell death in a prostate cancer mouse model.
multidisciplinary sciences
What problem does this paper attempt to address?
This paper discusses the effect of different pulse durations of Bipolar Irreversible Electroporation (IRE) on treatment outcomes in a prostate cancer mouse model. The study found that IRE with a longer pulse duration (300 microseconds) at the same voltage effectively induced cell death, increased tumor necrosis ratio, and resulted in higher apoptosis and cell death rates compared to a shorter pulse duration (100 microseconds). IRE is a non-thermal ablation technique used for local tumor treatment, and its effectiveness is influenced by pulse duration and voltage settings. The research also showed that long pulse duration IRE can enlarge the ablation zone and potentially reduce side effects such as muscle contraction and arrhythmia caused by high voltage. In addition, the effectiveness of IRE in vivo and in vitro was evaluated through methods including cell culture, live and dead cell detection, ROS generation, and magnetic resonance imaging, demonstrating the potential of extending pulse duration in prostate cancer treatment. However, the study also pointed out the need for further exploration to determine the optimal IRE parameters to enhance tumor necrosis and reduce associated complications.