Dynamic stabilisation of magnetic fields measured inside a magnetically shielded room using an external coil system

Jiye Zhao,Pengtao Tian,Jinji Sun,Haifeng Zhang
DOI: https://doi.org/10.1088/1361-6463/ad3147
2024-03-09
Journal of Physics D Applied Physics
Abstract:Magnetoencephalography (MEG) system based on optically pumped magnetometers (OPMs) requires a magnetically shielded room (MSR) to establish a stable near-zero field environment. Affected by external environmental electromagnetic interference, the magnetic noise in the MSR will become very severe. In order to overcome this problem, this paper proposes a method for dynamic stabilisation of magnetic fields measured inside a MSR using an external coil system. Firstly, the field form of the external compensation coil was analyzed by taking the AC characteristics of the material into consideration. Then, the linear characteristic of the control system is studied and a high performance magnetic noise suppression controller is designed based on the environment noise characteristics. Finally, simulation and experimental are carried out through a self-developed 1250mm×1250mm×2100mm MSR, which indicates that the proposed method can effectively suppress dynamic magnetic fluctuation and noise.
physics, applied
What problem does this paper attempt to address?