Spherical echo‐planar time‐resolved imaging (sEPTI) for rapid 3D quantitative T2* and susceptibility imaging

Nan Wang,Congyu Liao,Xiaozhi Cao,Mark Nishimura,Yannick W. E. Brackenier,Mahmut Yurt,Mengze Gao,Daniel Abraham,Cagan Alkan,Siddharth Srinivasan Iyer,Zihan Zhou,Hwihun Jeong,Adam Kerr,Justin P. Haldar,Kawin Setsompop
DOI: https://doi.org/10.1002/mrm.30255
2024-09-11
Magnetic Resonance in Medicine
Abstract:Purpose To develop a 3D spherical EPTI (sEPTI) acquisition and a comprehensive reconstruction pipeline for rapid high‐quality whole‐brain submillimeter T2* and QSM quantification. Methods For the sEPTI acquisition, spherical k‐space coverage is utilized with variable echo‐spacing and maximum kx ramp‐sampling to improve efficiency and signal incoherency compared to existing EPTI approaches. For reconstruction, an iterative rank‐shrinking B0 estimation and odd‐even high‐order phase correction algorithms were incorporated into the reconstruction to better mitigate artifacts from field imperfections. A physics‐informed unrolled network was utilized to boost the SNR, where 1‐mm and 0.75‐mm isotropic whole‐brain imaging were performed in 45 and 90 s at 3 T, respectively. These protocols were validated through simulations, phantom, and in vivo experiments. Ten healthy subjects were recruited to provide sufficient data for the unrolled network. The entire pipeline was validated on additional five healthy subjects where different EPTI sampling approaches were compared. Two additional pediatric patients with epilepsy were recruited to demonstrate the generalizability of the unrolled reconstruction. Results sEPTI achieved 1.4× faster imaging with improved image quality and quantitative map precision compared to existing EPTI approaches. The B0 update and the phase correction provide improved reconstruction performance with lower artifacts. The unrolled network boosted the SNR, achieving high‐quality T2* and QSM quantification with single average data. High‐quality reconstruction was also obtained in the pediatric patients using this network. Conclusion sEPTI achieved whole‐brain distortion‐free multi‐echo imaging and T2* and QSM quantification at 0.75 mm in 90 s which has the potential to be useful for wide clinical applications.
radiology, nuclear medicine & medical imaging
What problem does this paper attempt to address?