1212 Higher Is Not Always Better

Stephanie Chang,Jiyeon Seo,Oragun Rojanapairat
DOI: https://doi.org/10.1093/sleep/zsae067.01212
IF: 6.313
2024-04-20
SLEEP
Abstract:Abstract Introduction Positive airway pressure (PAP) is the recommended first line treatment for obstructive sleep apnea (OSA). Overnight titration studies can be performed to find the optimal PAP settings for patients. However, manual titration studies can lead to higher PAP settings. Report of case(s) Cases: A 69-year-old man with a body mass index (BMI) of 33 and severe OSA on continuous PAP (CPAP) 10 cm of H2O was referred to sleep clinic for worsening daytime fatigue. He had an in-lab titration study with a full-face mask and was successfully titrated to bilevel PAP (BPAP) with a final inspiratory PAP (IPAP) of 20 cm of H2O and expiratory PAP (EPAP) of 16 cm H2O. Notably during his sleep study, CPAP improved the AHI up to 14 cm H2O, but further increase in CPAP and switching to BPAP worsened the AHI until a final setting of BPAP 20/16 cm H2O was reached. A 75-year-old man with a BMI of 20 and moderate OSA was referred to sleep clinic for persistent daytime sleepiness despite compliant auto-CPAP use with nasal pillows. He underwent an in-lab titration study with a full-face mask and was titrated to BPAP settings of 22/17 cm of H2O. Review of his sleep study showed effective therapy at CPAP of 6 cm of H2O, but further titration on CPAP and BPAP worsened the AHI until a final setting of BPAP 22/17 cm of H2O was reached. Discussion: PAP settings are an important determinant for PAP compliance as patients often do not tolerate higher settings. Manual titration studies have shown to overestimate CPAP requirements compared to the use of auto-titrating PAP in uncomplicated OSA. Furthermore, full-face masks can paradoxically worsen upper airway obstruction and increase treatment pressures compared to nasal masks. It is thought that full-face masks can cause worsening of upper airway obstruction and lead to higher pressure requirements to pneumatically stent the airways. Conclusion In conclusion, manual PAP titration studies may exaggerate PAP requirements, especially with the use of full-face masks. Careful review of the titration and choice of mask should be an important consideration in treating OSA. Support (if any)
neurosciences,clinical neurology
What problem does this paper attempt to address?
The paper includes multiple case reports, each aimed at exploring the clinical management and treatment challenges of different sleep disorders. The specific issues addressed by each case report are as follows: 1. **Management of Refractory Restless Legs Syndrome (RLS)**: - The report describes the case of a 62-year-old Caucasian female patient with long-term and difficult-to-control RLS symptoms. The patient was intolerant to first-line medications and showed poor efficacy. By trying different opioids (such as methadone), researchers found that specific opioids could significantly improve symptoms. This case highlights the importance of individualized treatment for patients with refractory RLS. 2. **Facial Pressure Injury Caused by Continuous Positive Airway Pressure (CPAP) Mask**: - The case reports a 69-year-old male patient who developed facial pressure injuries from using a CPAP mask during an overnight titration study. This is the first reported case of such injuries caused by the use of the F&P Evora full-face mask, emphasizing the importance of proper mask fitting. 3. **Higher Positive Airway Pressure (PAP) Settings Are Not Necessarily Better**: - Through two cases, it is illustrated that manual PAP titration studies may lead to excessively high PAP settings, affecting patient compliance. The study shows that manual titration may overestimate the required pressure levels compared to auto-adjusting PAP and points out that full-face masks may exacerbate upper airway obstruction. 4. **Refractory Central Sleep Apnea Induced by Vagus Nerve Stimulation (VNS)**: - The case introduces a 69-year-old female epilepsy patient who developed refractory central sleep apnea after receiving VNS treatment. Using the SleepImage system to monitor sleep, researchers found that apnea significantly decreased after turning off the VNS, suggesting that VNS may induce or exacerbate sleep disorders. 5. **Jacobsen Syndrome with Mixed Sleep Apnea**: - The report describes a 3-month-old female infant with Jacobsen Syndrome and severe mixed sleep apnea. The study indicates that various features of Jacobsen Syndrome (such as hypotonia, craniofacial abnormalities, etc.) increase the risk of both obstructive and central sleep apnea, suggesting that sleep disorder screening should be conducted for such patients. 6. **Adjunctive Use of Solriamfetol for Excessive Daytime Sleepiness (EDS) in Pediatric Patients**: - The study explores the use of Solriamfetol in pediatric patients, a non-stimulant medication approved by the FDA for EDS related to adult OSA or narcolepsy. The research focuses on its effectiveness and potential benefits in children. In summary, these case reports aim to demonstrate the challenges in diagnosing, treating, and managing different types of sleep disorders through specific clinical examples and propose corresponding solutions.