Impact of Raman mapping area and intra-tablet homogeneity on the accuracy of sustained-release tablet dissolution prediction

Qi Zeng,Xin Gao,Long Wang,Guangpu Fang,Jiahe Qian,Hai Liu,Zheng Li,Wenlong Li
DOI: https://doi.org/10.1016/j.ejpb.2023.07.012
IF: 5.589
2023-07-31
European Journal of Pharmaceutics and Biopharmaceutics
Abstract:This exploratory study investigated the minimum required Raman mapping area for predicting sustained-release tablet dissolution profiles based on intra-tablet homogeneity. The aim was to minimize scanning time while achieving reliable dissolution profile predictions. To construct the sample set, we controlled the blending time to introduce variability in the homogeneity of the tablets. The dissolution prediction models were established using the partial least squares regression under different Raman mapping area. The accuracies of the prediction results were evaluated according to the difference factor f 1 and Intersection–Union two one-sided t-tests (IU TOST) methods, and the implications conveyed by the results were discussed. The results showed that the homogeneity of sustained-release tablet affects the minimum required mapping area, and the tablets with higher homogeneity show higher prediction accuracy when using the same mapping area to model the dissolution profiles of tablets.
pharmacology & pharmacy
What problem does this paper attempt to address?