Evaluation of a Condition Monitoring Algorithm for Early Bearing Fault Detection

Hannes Gruber,Anna Fuchs,Michael Bader
DOI: https://doi.org/10.3390/s24072138
IF: 3.9
2024-03-28
Sensors
Abstract:Roller bearings are critical components in various mechanical systems, and the timely detection of potential failures is essential for preventing costly downtimes and avoiding substantial machinery breakdown. This research focuses on finding and verifying a robust method that can detect failures early, without creating false positive failure states. Therefore, this paper introduces a novel algorithm for the early detection of roller bearing failures, particularly tailored to high-precision bearings and automotive test bed systems. The featured method (AFI—Advanced Failure Indicator) utilizes the Fast Fourier Transform (FFT) of wideband accelerometers to calculate the spectral content of vibration signals emitted by roller bearings. By calculating the frequency bands and tracking the movement of these bands within the spectra, the method provides an indicator of the machinery's health, mainly focusing on the early stages of bearing failure. The calculated channel can be used as a trend indicator, enabling the method to identify subtle deviations associated with impending failures. The AFI algorithm incorporates a non-static limit through moving average calculations and volatility analysis methods to determine critical changes in the signal. This thresholding mechanism ensures the algorithm's responsiveness to variations in operating conditions and environmental factors, contributing to its robustness in diverse industrial settings. Further refinement was achieved through an outlier detection filter, which reduces false positives and enhances the algorithm's accuracy in identifying genuine deviations from the normal operational state. To benchmark the developed algorithm, it was compared with three industry-standard algorithms: VRMS calculations per ISO 10813-3, Mean Absolute Value of Extremums (MAVE), and Envelope Frequency Band (EFB). This comparative analysis aimed to evaluate the efficacy of the novel algorithm against the established methods in the field, providing valuable insights into its potential advantages and limitations. In summary, this paper presents an innovative algorithm for the early detection of roller bearing failures, leveraging FFT-based spectral analysis, trend monitoring, adaptive thresholding, and outlier detection. Its ability to confirm the first failure state underscores the algorithm's effectiveness.
engineering, electrical & electronic,chemistry, analytical,instruments & instrumentation
What problem does this paper attempt to address?
The paper is primarily dedicated to addressing the issue of early detection of rolling bearing faults in mechanical systems, particularly in application scenarios involving high-precision bearings and automotive testing systems. The core objective of the research is to develop a method that can effectively and reliably identify early bearing faults to avoid costly downtime and severe equipment damage caused by bearing failures. The paper proposes a new algorithm called the "Advanced Fault Indicator" (AFI), which utilizes the Fast Fourier Transform (FFT) of broadband accelerometers to calculate the spectral components of vibration signals and monitors the health status of mechanical equipment by tracking changes in these frequency bands. The AFI algorithm focuses on early-stage bearing fault signs and is designed to reduce false alarms. Specifically, the AFI algorithm includes the following steps: 1. **Preprocessing**: Perform preprocessing operations such as filtering on the raw acceleration signal. 2. **Spectral Analysis**: Use FFT to convert the time-domain vibration signal to the frequency domain and extract key spectral features. 3. **Dynamic Threshold Setting**: Employ moving average and volatility analysis methods to determine thresholds, ensuring the algorithm can adapt to different working conditions and environmental factors. 4. **Outlier Detection**: Reduce false alarms through an outlier detection filter, improving the accuracy of the algorithm in identifying true deviations from normal operating conditions. 5. **Trend Monitoring**: Evaluate the health status of the equipment by monitoring trends in different frequency bands, with particular attention to high-frequency components related to early faults. To validate the effectiveness of the AFI algorithm, the researchers compared it with three industry-standard algorithms, including VRMS calculation according to ISO 10813-3, Mean Absolute Value Extremum (MAVE), and Envelope Frequency Band (EFB). Through such comparative analysis, the advantages and limitations of the new algorithm relative to existing methods were assessed. In summary, the paper introduces an innovative early bearing fault detection algorithm that improves fault detection accuracy through spectral analysis, trend monitoring, adaptive threshold setting, and outlier detection. This contributes to the implementation of predictive maintenance strategies, thereby reducing maintenance costs and downtime.