Free‐Breathing Ungated Radial Simultaneous Multi‐Slice Cardiac T1 Mapping

Johnathan V. Le,Jason K. Mendes,Konstantinos Sideris,Erik Bieging,Spencer Carter,Josef Stehlik,Edward V. R. DiBella,Ganesh Adluru
DOI: https://doi.org/10.1002/jmri.29676
IF: 4.4
2024-12-13
Journal of Magnetic Resonance Imaging
Abstract:Background Modified Look‐Locker imaging (MOLLI) T1 mapping sequences are acquired during breath‐holding and require ECG gating with consistent R‐R intervals, which is problematic for patients with atrial fibrillation (AF). Consequently, there is a need for a free‐breathing and ungated framework for cardiac T1 mapping. Purpose To develop and evaluate a free‐breathing ungated radial simultaneous multi‐slice (SMS) cardiac T1 mapping (FURST) framework. Study Type Retrospective, nonconsecutive cohort study. Population Twenty‐four datasets from 17 canine and 7 human subjects (4 males, 51±22 years; 3 females, 56±19 years). Canines were from studies involving AF induction and ablation treatment. The human population included separate subjects with suspected microvascular disease, acute coronary syndrome with persistent AF, and transthyretin amyloidosis with persistent AF. The remaining human subjects were healthy volunteers. Field Strength/Sequence Pre‐ and post‐contrast T1 mapping with the free‐breathing and ungated SMS inversion recovery sequence with gradient echo readout and with conventional MOLLI sequences at 1.5 T and 3.0 T. Assessment MOLLI and FURST were acquired in all subjects, and American Heart Association (AHA) segmentation was used for segment‐wise analysis. Pre‐contrast T1, post‐contrast T1, and ECV were analyzed using correlation and Bland–Altman plots in 13 canines and 7 human subjects. T1 difference box plots for repeated acquisitions in four canine subjects were used to assess reproducibility. The PIQUE image quality metric was used to evaluate the perceptual quality of T1 maps. Statistical Tests Paired t‐tests were used for all comparisons between FURST and MOLLI, with P<0.05 indicating statistical significance. Results There were no significant differences between FURST and MOLLI pre‐contrast T1 reproducibility (25±18 and 19±16msec , P=0.19 ), FURST and MOLLI ECV (29%±11% and 28%±11% , P=0.05 ), or FURST and MOLLI PIQUE scores (52±8 and 53±10 , P=0.18 ). The ECV mean difference was 0.48 with 95%CI:6.0×10−4,0.96 . Conclusions FURST had similar quality pre‐contrast T1, post‐contrast T1, and ECV maps and similar reproducibility compared to MOLLI. Level of Evidence 3 Technical Efficacy 1
radiology, nuclear medicine & medical imaging
What problem does this paper attempt to address?