Intraoperative assessment of the dorso-ulnar fragment stability with stress fluoroscopy: An observational study

Mehmet Fevzi Cakmak,Levent Horoz,Cihan Kircil,Galip Beltir,Hakki Cagdas Basat
DOI: https://doi.org/10.1097/md.0000000000038509
IF: 1.6
2024-06-15
Medicine
Abstract:Distal radius fractures (DRFs) are frequently encountered in daily orthopedic practice. Anatomic reduction and adequate fixation are the key success for DRFs. Various techniques described for DRF surgery depend on severity. Single volar-locking plate (VLP) fixation, single dorsal plate fixation, or fragment-specific fixation modalities achieve stable fixation. [ 1 ] VLP fixation for DRFs is the most common treatment for such fractures. [ 2 ] Dorso-ulnar fragment (DUF) plays an important role in stabilizing the dorsal rim by inserting the dorsal distal radioulnar ligaments and preventing dorsal tilt. [ 3 ] However, Arbeitsgemeinschaft für Osteosynthesefragen (AO) type C comminuted fractures can be treated with a VPL. [ 4 ] There are difficulties in the fixation of the DUF over the VPL because of the size of the fragment and the variation of the sigmoid notch. [ 5 ] Rozental et al [ 6 ] found that only volar fixation of the DUF leads to dorsal collapse and reduction losses. Dorsal plate applications are performed to prevent dorsal collapse and obtain adequate fixation. [ 7 ] In volar and combined plate applications, tendon irritation and high implant evacuation rates have been shown, depending on the dorsal protrusion of the screw applied from the volar plate and the profile of the applied dorsal plate. [ 8 , 9 ] Volar and combined dorsal fixation for AO type C fracture showed similar radiological and clinical results. [ 10 ] Although there is no consensus on applying a volar or combined plate in comminuted DRFs fixation, it has been shown that penetration of the DUF fragment by only 1 screw through the VPL is sufficient to ensure DUF stability. [ 11 ] It has been shown that in the intraoperative evaluation of the adequate fixation of the DUF fragment with the volar plate, conventional fluoroscopy will often be insufficient, and the screw distribution to the fragments will be more accurate when the fixation is made under computed tomography (CT) guidance. [ 12 ] Although intraoperative CT has advantages in evaluating DUF fragment fixation in DRFs, it is not widely used because it requires special equipment. Intraoperative stress fluoroscopy is commonly used to evaluate fixation stability. [ 13 , 14 ] Stress radiographs provide the opportunity to assess stability after fracture fixation dynamically. The study aims to evaluate the effectiveness of using stress radiographs during volar plate application in comminuted DRFs for accurate fragment fixation by comparing it with surgery performed with conventional fluoroscopy.
medicine, general & internal
What problem does this paper attempt to address?