Numerical study of particle deposition characteristics in a new type of reinforced pipe
Lei Liu,Ying Xi,Lin Zhang,Weigang Xu,Rui Zhao,Yi Liu,Zelin Wang,Bingjie Wu,Kexin Dong
DOI: https://doi.org/10.1016/j.cep.2023.109371
IF: 4.264
2023-07-01
Chemical Engineering and Processing - Process Intensification
Abstract:When the heat exchanger is working, the medium often contains small impurity particles. Some particles will form dirt in the tubeline during operation, thus increasing energy consumption. This paper presents a new type of reinforced heat exchange tube. The Lagrange model and User-defined Function (UDF) in FLUENT software are used to compile the particle deposition judgment conditions, establish the particle ablation model, and study the effects of inlet flow rate, inlet temperature and particle size on the particle deposition characteristics of straight, twisted and new tubes. The liquid results showed that when the inlet flow rate is 0.6 m/s, the inlet cooling water temperature is 27 °C, the outer wall temperature is 78 °C, the wall roughness is 0.05 mm, and the particle size is 1 μm. When the particle mass flow rate is 0.0005 kg/s, the particle deposition rate in the new tube reaches the minimum value of 30.1% at 19.2 h These data showed that the structure of the new tubeline will not only cause the fluid to rotate, but also cause the fluid to expand and contract, thus increasing the turbulence. The new enhanced heat exchange tube has excellent performance in inhibiting particle deposition.
energy & fuels,engineering, chemical