Fluorescence Multi-Detection Device Using a Lensless Matrix Addressable microLED Array

Victor Moro,Joan Canals,Sergio Moreno,Steffen Bornemann,Oscar Alonso,Andreas Waag,J. Daniel Prades,Angel Dieguez
DOI: https://doi.org/10.3390/bios14060264
2024-05-23
Biosensors
Abstract:A Point-of-Care system for molecular diagnosis (PoC-MD) is described, combining GaN and CMOS chips. The device is a micro-system for fluorescence measurements, capable of analyzing both intensity and lifetime. It consists of a hybrid micro-structure based on a 32 × 32 matrix addressable GaN microLED array, with square LEDs of 50 μm edge length and 100 μm pitch, with an underneath wire bonded custom chip integrating their drivers and placed face-to-face to an array of 16x16 single-photon avalanche diodes (SPADs) CMOS. This approach replaces instrumentation based on lasers, bulky optical components, and discrete electronics with a full hybrid micro-system, enabling measurements on 32 × 32 spots. The reported system is suitable for long lifetime (>10 ns) fluorophores with a limit of detection ~1/4 μM. Proof-of-concept measurements of streptavidin conjugate QdotTM 605 and Amino PEG QdotTM 705 are demonstrated, along with the device ability to detect both fluorophores in the same measurement.
chemistry, analytical,nanoscience & nanotechnology,instruments & instrumentation
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to develop a portable medical device (Point - of - Care, PoC) suitable for molecular diagnosis, especially for the application of fluorescence multi - detection. Specifically, the researchers designed a fluorescence multi - detection device using a lensless matrix - addressable micro - light - emitting diode (microLED) array. This device aims to overcome the limitations of relying on lasers, bulky optical components and discrete electronic components in traditional fluorescence detection methods, and realizes the simultaneous measurement of 32 × 32 points through a fully integrated microsystem. In addition, this device can also perform two types of fluorescence measurements, intensity and lifetime, is suitable for long - lived (> 10 nanoseconds) fluorophores, and has a detection limit of about 1/4 μM. The study demonstrated the performance of this device in simultaneously detecting different fluorophores (such as streptavidin conjugate Qdot™ 605 and Amino PEG Qdot™ 705). ### Background of the Paper With the intensification of the global population aging trend, the demand for medical services has increased significantly, especially in low - and middle - income countries. These regions usually face problems such as resource scarcity, understaffing and weak infrastructure, which lead to delayed disease diagnosis, affecting patient safety and the control of disease spread. Therefore, the development of a rapid diagnosis platform to improve diagnosis efficiency and reduce diagnosis time has become an urgent need. ### Solution This paper introduces a portable molecular diagnosis system (PoC - MD) that combines GaN and CMOS chips. This system is a microsystem for fluorescence measurement and can simultaneously analyze fluorescence intensity and lifetime. The core of the system is a 32 × 32 matrix - addressable GaN micro - LED array, with each LED having a side length of 50 μm and a pitch of 100 μm. A custom - made CMOS chip integrated with a driver is connected below the array by wire bonding and is placed face - to - face with a 16 × 16 single - photon avalanche diode (SPAD) CMOS array. This design replaces traditional instruments based on lasers, bulky optical components and discrete electronic components and enables the measurement of 32 × 32 points. ### Technical Advantages 1. **High Brightness and High - speed Modulation**: GaN - based micro - LEDs have high brightness and a modulation bandwidth of up to 1 GHz, making them a suitable substitute for lasers, especially for time - resolved fluorescence measurement. 2. **No Need for Optical Components**: This system can perform intensity and time - correlated fluorescence measurements without using any optical components, thus achieving miniaturization and cost reduction. 3. **Multiplexing Capability**: The 32 × 32 micro - LED array allows the simultaneous detection of multiple sample points, improving detection efficiency. ### Experimental Verification The researchers experimentally verified the performance of this system, including the fluorescence intensity and lifetime measurements of quantum dots (QD605 and QD705) at different concentrations. The results show that this system can detect a fluorophore concentration of 1/4 μM and can distinguish fluorophores with different lifetimes. ### Conclusion This study has successfully developed a portable fluorescence multi - detection device suitable for molecular diagnosis, which has high sensitivity, multiplexing capability and cost - effectiveness. This technology is expected to provide rapid and accurate disease diagnosis in resource - limited environments and improve the quality of medical services.