Self-Sustaining Water Microdroplet Resonators Using 3D-Printed Microfluidics

Parker A. Awerkamp,David Hill,Davin Fish,Kimi Wright,Brandt Bashaw,Gregory P. Nordin,Ryan M. Camacho
DOI: https://doi.org/10.3390/mi15040423
IF: 3.4
2024-03-23
Micromachines
Abstract:Microdroplet resonators provide an excellent tool for optical studies of water, but water microdroplets are difficult to maintain outside a carefully controlled environment. We present a method for maintaining a water microdroplet resonator on a 3D-printed hydrophobic surface in an ambient environment. The droplet is maintained through a passive microfluidic system that supplies water to the droplet through a vertical channel at a rate equivalent to its evaporation. In this manner, we are able to create and passively maintain water microdroplet resonators with quality factors as high as 3×108.
chemistry, analytical,nanoscience & nanotechnology,instruments & instrumentation,physics, applied
What problem does this paper attempt to address?
The problem that this paper attempts to solve is how to maintain the stability and optical properties of water micro - droplet resonators under environmental conditions. Specifically, water micro - droplets form perfect spheres due to their surface tension, making them ideal optical resonators. However, water micro - droplets are prone to evaporation under environmental conditions, resulting in changes in their size and thus affecting their optical performance. To solve this problem, the author proposes a method of using a 3D - printed microfluidic system to maintain water micro - droplet resonators. This method supplies water to the micro - droplets through a vertical channel to compensate for their evaporation rate, thereby achieving passive maintenance of the micro - droplets. This method can not only precisely control the size of the micro - droplets but also maintain the stability of the micro - droplets without adding stabilizers or special environments, making their quality factor (Q - value) as high as \(3\times10^{8}\). ### Main problems 1. **Evaporation problem of water micro - droplets**: Water micro - droplets are prone to evaporation under environmental conditions, resulting in unstable size and affecting their performance as optical resonators. 2. **Precise control of micro - droplet size**: Traditional micro - droplet generation methods are difficult to precisely control the size of micro - droplets. 3. **Maintaining high Q - value**: How to maintain the high Q - value of water micro - droplet resonators under environmental conditions so that they are suitable for various optical studies. ### Solutions 1. **3D - printed microfluidic system**: A 3D - printed microfluidic system is designed. Water is supplied to the micro - droplets through a vertical channel to compensate for their evaporation rate, thereby achieving passive maintenance of the micro - droplets. 2. **Precise control of micro - droplet size**: By adjusting the height of the water reservoir, the size of the micro - droplets can be precisely controlled to reach the required size. 3. **Maintenance of high Q - value**: Through the above - mentioned methods, the high Q - value of water micro - droplet resonators can be maintained without adding stabilizers or special environments, with a maximum value of up to \(3\times10^{8}\). ### Experimental results - The effectiveness of this method has been verified through experiments, and stable water micro - droplets with a diameter between 300 μm and 600 μm have been successfully generated. - The optimal water reservoir heights required for micro - droplets with different diameters have been measured and compared with theoretical calculation values. It has been found that the actual height is higher than the theoretical value, but the change trend is the same. - Optical measurement results show that the generated water micro - droplet resonators have a very high Q - value, with a maximum value of up to \(6.25\times10^{8}\). ### Discussion - **Reasons for high Q - value**: Factors that may affect the Q - value are discussed, including material absorption, surface scattering, and radiation loss. Although theoretical calculations indicate that water absorption limits the Q - value, experimental results show a higher Q - value. The author excludes factors such as thermal bistability and micro - droplet size instability and believes that it may be because the resonant wavelength of the micro - droplets changes too fast, making the laser scanning direction unimportant. - **Application prospects**: This method provides a new platform for future research involving water micro - droplet resonators, and has important application value especially in the research of biological and physical phenomena. In conclusion, this paper successfully solves the stability problem of water micro - droplet resonators under environmental conditions through an innovative 3D - printed microfluidic system, providing strong support for research in related fields.