Pharmacokinetics and Pharmacodynamics of 40/60 Premixed Recombinant Human Insulin Injection Preparations
Yuan Tao,Zhao Weigang,Fu Yong,Dong Yingyue,Sun Qi
DOI: https://doi.org/10.3760/cma.j.issn.1674-635x.2016.01.001
2016-01-01
Abstract:Objective To study the pharmacokinetics and pharmacodynamics of the 40/60 premixed recombinant human insulin injection preparation,and to compare with 30/70 preparation,regular insulin,and neutral protamine Hagedorn (NPH).Methods In this positive control,single dose,open label,Latin square crossover study,20 male healthy volunteers were recruited from May 2006 to March 2007,and divided into four groups.On 4 test days,40/60 preparation,30/70 preparation,regular insulin,and NPH were administered to each of the 4 groups,the interval was 7-70 days before 2 test days.The pharmacokinetics and pharmacodynamics were evaluated by euglycemic glucose clamp technique.Results According to the analysis of variance,there were statistically significant differences in pharmacokinetics and pharmacodynamics of the 4 insulin formulations between the 4 groups (all P < 0.05).For the 40/60 premixed recombinant human insulin,the pharmacokinetic parameter time to peak (Tmax) and mean retention time (MRT) were (105.00 ±24.33) minutes and (321.77 ± 56.29) minutes,respectively;the glucose-lowering effects reflected by the pharmacodynamic parameter Tmax and MRT were (167.75 ± 26.48) minutes and (248.33 ± 14.96) minutes,respectively.Compared with 30/70 premixed recombinant human insulin,40/60 preparation showed no significant differences in the pharmacokinetics parameters of blood insulin concentration,including peak concentration [(91.67 ± 13.03) mU/L vs.(84.96 ± 14.75) mU/L,P =0.119],Tmax [(105.00 ± 24.33) minutes vs.(122.25 ± 39.35) minutes,P =0.128],MRT [(321.77 ± 56.29) minutes vs.(332.12 ± 49.20) minutes,P =0.645] and area under the curve in 0-16 hours [AUCIns 0-16,(24 918 ± 6 610)h · mU/L vs.(26 768 ± 8 032)h· mU/L,P=0.084];however,statistically significant differences were observed in AUCIns0-4 [(16 991 ± 3 673) h · mU/L vs.(12 407 ± 3 441) h · mU/L,P =0.042] and AUCIns 0-8 [(23 283 ± 4 939) h · mU/L vs.(19 397 ±5 314)h · mU/L,P =0.046].Pharmacodynamic parameters showed no statistically significant differences (all P > 0.05).Compared with 30/70 premixed insulin,the relative bioavailability of 40/60 premixed insulin was (118.9 ± 35.9) %,and the relative biological effectiveness was (106.6 ± 35.2) %.There was no clinically significant abnormalities in the safety indexes before and after the tests.No hypoglycemic events,allergic reactions,or local injection adverse reaction occurred in this trial.Conclusions The 40/60 premixed recombinant human insulin preparation demonstrated different properties in insulin absorption in 8 hours after injection compared with the 30/70 preparation,mainly because of the difference in proportions of short-and intermediate-acting insulin in the mixture.This new premixed insulin may provide a new option for personalized diabetes management.