Establishment and Application of a Duplex Real Time Fluorogenic Quantitative PCR Assay System for Mir-451A and Mir-21-5p
Hu Shu-Xiao,Chen Hui-Xiang,Hu Sheng,Zhao Yi-Xia,Ji An-Quan,Li Yang,Lian Jie,Sun Qi-Fan
DOI: https://doi.org/10.16476/j.pibb.2023.0211
2024-01-01
PROGRESS IN BIOCHEMISTRY AND BIOPHYSICS
Abstract:Objective Body fluid stains left at crime scenes are frequently trace amounts, while the identification of body fluids through real time fluorogenic quantitative technique often necessitates the repeated detection within the limited sample, as multiple miRNA markers are the basis for the identification. Based on the goal of both the throughput and efficiency improvement of miRNA analysis in trace samples, a duplex real time fluorogenic quantitative PCR assay system was designed to accurately quantify two miRNAs simultaneously, and the system should be further verified by actual sample for the body fluid identification. Methods The duplex real time fluorogenic quantitative PCR system of miR-451a to miR-21-5p was established with specially designed primers and probes, and the concentrations of the primers and probes were both optimized. The specificity, sensitivity and reproducibility of the system were validated, while its capability for body fluid identification was assessed using the miR-451a to miR-21-5p ratio. Results The optimized assay system exhibited excellent specificity and repeatability, with coefficients of variation consistently below 8% for both intra- and inter -batch variability. The amplification efficiency of miR-451a and miR-21-5p reached 71.77% and 74.81%, respectively, with high and relatively consistent results. By utilizing this duplex real time fluorogenic quantitative PCR assay system, a total of 58 body fluid samples were analyzed, exhibiting a discrimination rate of 100% between blood and non -blood samples, as well as between peripheral blood and menstrual blood samples. Moreover, the results, obtained from single real time fluorogenic quantitative PCR assay system and duplex real time fluorogenic quantitative PCR assay system, showed no statistically significant difference with randomly selected blood samples (n=20). Compared to previous single real time fluorogenic quantitative PCR assay system, the sensitivity of duplex real time fluorogenic quantitative PCR assay system exhibited remarkable improvement. A minimum input of only 0.1 ng total RNA was sufficient for accurate detection of peripheral blood and menstrual blood samples, while saliva, semen, and vaginal secretion required only 1 ng total RNA for precise identification purposes. Additionally, the duplex real time fluorogenic quantitative PCR assay system successfully differentiated between different types of body fluids in simulated samples under natural outdoor conditions. Conclusion The duplex real time fluorogenic quantitative PCR assay system effectively reduced both the time and material costs by half compared to the single system, especially suitable for the examination of body fluid stains left at crime scenes, solving the contradiction between the trace amount and the multiple sample volumes demand of repeated real time fluorogenic quantitative PCR. The duplex real time fluorogenic quantitative PCR assay successfully distinguished blood and other body fluid, as well as peripheral blood and menstrual blood samples, which maintains an equivalent capability for body fluid identification with half sample, time and reagent consumption. This system provides an efficient tool for identifying suspicious body fluids, as well as a foundation for more multiplexed real time fluorogenic quantitative PCR assay system research.