Comparison of HASTE versus EPI-Based DWI for Retinoblastoma and Correlation with Prognostic Histopathologic Parameters

Manish Sharma,Amit Gupta,Manisha Jana,Seema Kashyap,Sameer Bakhshi,Sanjay Sharma
DOI: https://doi.org/10.3174/ajnr.a8084
IF: 4.9661
2024-02-08
American Journal of Neuroradiology
Abstract:BACKGROUND AND PURPOSE: Non-EPI-based DWI has shown better performance in head and neck pathologies owing to lesser susceptibility artifacts compared with EPI-DWI. However, only sporadic studies have investigated the feasibility of non–EPI-based DWI in retinoblastoma (RB). We qualitatively and quantitively compared EPI-DWI and HASTE-DWI in RB and correlated the tumor ADC values obtained from these 2 techniques with histopathologic markers. MATERIALS AND METHODS: Twenty-one treatment-naive patients with RB underwent 1.5T orbital MR imaging. EPI-DWI and HASTE-DWI were acquired at 3 b-values (0, 500, and 1000 s/mm 2 ). All patients subsequently underwent surgical enucleation. For qualitative image assessment, scoring of overall image quality, artifacts, tumor sharpness, and tumor conspicuity was done by using a 5-point Likert scale. Quantitative assessment included calculations of SNR, contrast-to-noise ratio (CNR), geometric distortion, and ADC. Qualitative scores were compared by using the Wilcoxon signed-rank test, and quantitative parameters were analyzed with a t test. RESULTS: All 21 patients had unilateral RB; 15 were male and 6 were female with a median age of 36 months (range, 9–72 months). On histopathology, patients had either poorly differentiated ( n = 13/21) or moderately differentiated ( n = 8/21) RB. Other poor prognostic markers evaluated were optic nerve invasion ( n = 10/21), choroidal invasion ( n = 12/21), and anterior eye segment enhancement on MRI ( n = 6/21). HASTE-DWI demonstrated higher image quality scores than EPI-DWI ( P < .01), except for tumor conspicuity score, which was higher for EPI-DWI ( P < .001). HASTE-DWI showed lower SNR, CNR, and geometric distortion than EPI-DWI ( P < .001). The average acquisition times of EPI-DWI and HASTE-DWI were ~1 and 14 minutes, respectively. The mean tumor ADC value on EPI-DWI was 0.62 ± 0.14 x 10 –3 mm 2 /s and on HASTE-DWI was 0.83 ± 0.17 x 10 –3 mm 2 /s. A significant correlation between EPI-DWI and HASTE-DWI ADC values ( r = 0.8; P = .01) was found. Lower ADC values were found in tumors with poor prognostic markers, but none reached a statistically significant difference. CONCLUSIONS: HASTE-DWI shows improved overall image quality; however, it lacks in terms of tumor conspicuity, SNR, CNR, and longer acquisition time compared with EPI-DWI. ADC values derived from HASTE-DWI show no advantage over EPI-DWI in correlation with histopathologic prognostic markers.
radiology, nuclear medicine & medical imaging,clinical neurology,neuroimaging
What problem does this paper attempt to address?