High-precision MC-ICP-MS Static Measurements of Uranium Isotopes Using Faraday Cups
Mangu Jin,Yanuo Jiao,Yue Liu,Qingfeng Shao,Xinggong Kong,Yongjin Wang
DOI: https://doi.org/10.1360/tb-2021-1152
2022-01-01
Abstract:High-precision measurements of U-238/U-235 and U-234/U-238 atomic ratios are essential for U-Pb and Th-230/U dating, as well as for a wide range of Earth and environmental studies. The U-238/U-235 ratio of a natural material has been considered to be a constant of 137.88 since the 1970s. However, recent advances in analytical techniques, such as TIMS (Thermal Ionization Mass Spectrometry) and MC-ICP-MS (Multiple Collector Inductively Coupled Plasma Mass Spectrometry), allowed the measurement of U-238/U-235 ratios at a precision of 10(-5), revealing up to 5% variations in terrestrial U-238/U-235 ratios. The U-234/U-238 ratios are commonly observed at the 10(-4)-10(-5) levels in the natural environment. These large differences in abundance make it impossible to simultaneously measure U isotopes in Faraday cups connected to the standard 10(11) Omega current amplifiers using the MC-ICP-MS. To obtain epsilon precision levels in the U-234/U-238 measurements, previous studies employed a 10(9) or 10(10) Omega amplifier for the U-238 Faraday cup and a 10(11) Omega amplifier for the U-234 Faraday cup. However, these methods require a large quantity of sample material of 400-1000 ng U-238, as the 10(11) Omega amplifier has a relatively low signal/noise ratio. In 2014, Thermo Fisher Scientific launched a new Faraday cup current amplifier with a 10(13) Omega feedback resistor, which offers a signal/noise ratio improved by a factor of five compared with standard 10(11) Omega amplifiers. Therefore, we are attempting to use the new 10(13) Omega amplifier in combination with the 10(11) and 10(12) Omega amplifiers to perform high-precision static measurements of U isotopes with Faraday cups using a small amount of sample. In the present study, we simultaneously used a 10(13) Omega amplifier, two 10(12) Omega amplifiers, and two 10(11) Omega amplifiers for the U-234, the U-233 and U-236, and the U-235 and U-238 Faraday cups, respectively. To evaluate the relative gain of the 10(13) Omega current amplifier prior to sample analyses, we repeated the measurements of the U-238/U-235 ratios in a uranium solution with Faraday cups connected to 10(13) and 10(11) Omega amplifiers. The relative gain of the 10(13) Omega amplifier was calculated as (U-238(11)/U-235(13))/(U-238(11)/U-235(11)), where the subscript indicates the resistors of the Faraday cup amplifiers. We also developed approaches to correct for the effects of baseline, memory, tailing, hydride, and mass biases. Using the new static measurement method, we repeatedly measured U-234/U-238 and U-238/U-235 ratios for the international uranium standards HU-1 and SRM950a, as well as for the national uranium standards GBW04412 and GBW04428. Our results (presented with +/- 2 sigma) show that the international standards HU-1 (n=10) and SRM950a (n=10) have U-234/U-238 atomic ratios of (54.90 +/- 0.03)x10(-6) and (53.88 +/- 0.03)x10(-6), and U-238/U-235 ratios of 137. 765 +/- 0.010 and 137.844 +/- 0.005, respectively. On the other hand, the national standards GBW04412 (n=8) and GBW04428 (n=10) have U-234/U-238 ratios of (101.66 +/- 0.04)x10(-6) and (53.86 +/- 0.03)x10(-6), and U-238/U-235 ratios of 137.786 +/- 0.018 and 137.995 +/- 0.008, respectively. Our results are consistent with previously published data and demonstrated high reliability. Our study shows that using the new method we can rapidly measure U-234/U-238 and U-238/U-235 ratios with precision of 0.3 parts per thousand-1 parts per thousand and 0.3 epsilon-0.7 epsilon, respectively, consuming 20-30 ng uranium within similar to 20 min. In addition, our method is flexible: The combination of different amplifiers can be easily modified according to the characteristics of the analyzed samples and the required measurement precision.