A practical approach of measuring $^{238}$U and $^{232}$Th in liquid scintillator to sub-ppq level using ICP-MS

Yuanxia Li,Jie Zhao,Yayun Ding,Tao Hu,Jiaxuan Ye,Jian Fang,Liangjian Wen
2024-05-10
Abstract:Liquid scintillator (LS) is commonly utilized in experiments seeking rare events due to its high light yield, transparency, and radiopurity. The concentration of $^{238}$U and $^{232}$Th in LS consistently remains below 1 ppq (10$^{-15}$ g/g), and the current screening result is based on a minimum 20-ton detector. Inductively coupled plasma mass (ICP-MS) spectroscopy is well-regarded for its high sensitivity to trace $^{238}$U and $^{232}$Th. This study outlines a method for detecting $^{238}$U and $^{232}$Th in LS at the sub-ppq level using ICP-MS, involving the enrichment of $^{238}$U/$^{232}$Th from the LS through acid extraction. With meticulous cleanliness control, $^{238}$U/$^{232}$Th in approximately 2 kg of LS is concentrated by acid extraction with 0.4 (0.3) pg $^{238}$U ($^{232}$Th) contamination. Three standard adding methods are employed to assess recovery efficiency, including radon daughter, 2,5-diphenyloxazole (PPO), and natural non-existent $^{233}$U/$^{229}$Th. The method detection limit at a 99% confidence level of this approach can reach approximately 0.2-0.3 ppq for $^{238}$U/$^{232}$Th with nearly 100% recovery efficiency.
Instrumentation and Detectors,Nuclear Experiment
What problem does this paper attempt to address?
The paper attempts to address the issue of measuring the concentrations of 238U and 232Th in liquid scintillators (LS) to achieve sub-ppq (10^-15 g/g) levels. Currently, the concentrations of 238U and 232Th in liquid scintillators in large detectors can be controlled below 1 ppq, but these results are usually based on detectors of at least 20 tons. To improve the sensitivity and accuracy of the experiments, researchers need to develop a method that can measure the concentrations of 238U and 232Th in small laboratory-scale samples (such as a few kilograms of liquid scintillator) to sub-ppq levels. Specifically, the paper proposes a method using inductively coupled plasma mass spectrometry (ICP-MS) combined with acid extraction to concentrate and detect 238U and 232Th in liquid scintillators. Through this method, researchers hope to achieve the following goals: 1. **Improve detection sensitivity**: Lower the detection limits of 238U and 232Th to sub-ppq levels. 2. **Reduce external contamination**: Ensure minimal external contamination during sample handling through strict cleanliness control measures. 3. **Verify recovery efficiency**: Evaluate and verify the recovery efficiency of 238U and 232Th by adding standard samples, ensuring the reliability and accuracy of the method. In summary, this study aims to develop an efficient, accurate, and repeatable method for measuring the concentrations of 238U and 232Th in small laboratory-scale samples of liquid scintillators, thereby providing more precise radiopurity data for high-energy physics experiments.