Tracking interfacial changes of graphene/Ge(110) during in-vacuum annealing

L. Camilli,M. Galbiati,L. Di Gaspare,M. De Seta,I. Píš,F. Bondino,A. Caporale,V. -P. Veigang-Radulescu,S. Hofmann,A. Sodo,R. Gunnella,L. Persichetti,V.-P. Veigang-Radulescu
DOI: https://doi.org/10.48550/arXiv.2204.02037
2022-04-05
Materials Science
Abstract:Graphene quality indicators obtained by Raman spectroscopy have been correlated to the structural changes of the graphene/Germanium interface as a function of in-vacuum thermal annealing. Specifically, it is found that graphene becomes markedly defected at 650 {\deg}C. By combining scanning tunneling microscopy, x-Ray Photoelectron Spectroscopy and Near Edge x-ray Absorption Fine Structure Spectroscopy, we conclude that these defects are due to the release of H_{2} gas trapped at the graphene/Germanium interface. The H_{2} gas was produced following the transition from the as-grown hydrogen-termination of the Ge(110) surface to the emergence of surface reconstructions in the substrate. Interestingly, a complete self-healing process is observed in graphene upon annealing to 800 {\deg}C. The subtle interplay revealed between the microscopic changes occurring at the graphene/Germanium interface and graphene's defect density is valuable for advancing graphene growth, controlled 2D-3D heterogeneous materials interfacing and integrated fabrication technology on semiconductors.
What problem does this paper attempt to address?