The Trombe Wall Equipped with PCMs for the Enhancement of the Indoor Thermal Quality

Yuan Zhang,Ziyang Zhu,Zian Peng,Jing Luo,Xiaoqin Sun,Jie Li,Fen Peng
DOI: https://doi.org/10.1016/j.enbuild.2023.113407
IF: 7.201
2023-08-10
Energy and Buildings
Abstract:A building with Trombe wall and phase change materials (PCMs) was designed, developed, tested and simulated to investigate the thermal comfort variation under various operation conditions. Eight models with different PCMs and ventilation modes were simulated and validated against experimental data. The thermal performance throughout the entire year was analyzed using indexes as integrated indoor discomfort degree-hour (I DH ) and integrated indoor discomfort duration (I D ). The findings indicate a strong correlation between the indoor thermal comfort and ventilation strategy, PCMs type and PCMs position. Ventilation with the presence of PCM25 at the inside layer of the Trombe wall is the most efficient approach to reduce the integrated indoor thermal discomfort degree-hour with a value of 12857 °C·h with a penalty of longer indoor discomfort duration. However, for no ventilation condition, it is recommend to adopt the Trombe wall with PCM28 at the outside layer and PCM18 at the inside layer. The lowest integrated indoor thermal discomfort degree-hour was 13914 °C·h. The lowest integrated indoor discomfort duration of 3009 hours was obtained with the single Trombe wall without ventilation in the entire year.
energy & fuels,construction & building technology,engineering, civil
What problem does this paper attempt to address?