PERFORMANCE ANALYSIS OF LOW GWP REFRIGERANTS IN A NOVEL DIRECT EXPANSION SOLAR ASSISTED EJECTORHEAT PUMP SYSTEM

Lingeng Zou,Ye Liu,Jianlin Yu
DOI: https://doi.org/10.18462/iir.hfo2023.0018
2023-01-01
Abstract:A novel direct expansion solar assisted ejectorexpansion enhanced heat pump cycle (DX-SEEHP) for heat pump drying applications is proposed. A thermodynamic analysis model of the cycle is established and the performance of DX-SEEHP and conventional ejector expansion heat pump system (EEHP) is comprehensively analysed. Compared to the EHP, the research shows that the DX-SEHP with R134a refrigerant has a 23.64%-39.82% increase in heating performance COPh and 32.79%-33.96% increase in volumetric heating capacity for the given condensing temperature range (T-c from 60 degrees C to 80 degrees C). Finally, the cycle performance of five low-GWP (GWP<1000) alternative refrigerants (R1234yf, R1234ze(E) and R1233zd(E)) are presented and compared with R134a. Among them, R1234yf shows excellent thermal performance with the highest COPh 5.40 and high Q(cv) 4691.11 kJ center dot m(-3), being the best alternative refrigerant to R134a.