Comparative Study on Asymmetric and Symmetric Configurations of Valve Plates in Axial Piston Pumps

Yijie Lu,Hua Fang,Bo Yang,Haoyi Jiang,Zhenfei Ling,Hao Liu,Xiaoping Ouyang,Huayong Yang
DOI: https://doi.org/10.1115/fpmc2024-140112
2024-01-01
Abstract:Abstract Using asymmetric cylinders to replace symmetric cylinders effectively reduces the volume and weight of electro-hydrostatic actuators (EHAs). However, asymmetric cylinders have the flow mismatch between the rod and rodless chambers. Researchers proposed using the three-port asymmetric valve plate (AVP) to solve the flow mismatch problem without increasing the weight and volume of the EHA. However, compared with the traditional symmetric valve plate (SVP), the impact of the AVP on the performance of the axial piston pump has yet to be studied. This paper establishes a mixed lubrication model of the cylinder block/valve plate interface considering asperity contact, and compares the oil film characteristics of AVP and SVP. It is found that the cylinder block overturning behavior caused by the AVP is more prominent than that of the SVP. At the same time, by establishing a lumped parameter model of the axial piston pump, the flow characteristics of AVP and SVP under different operating conditions are compared, revealing the impact of AVP on the flow ripple of the axial piston pump. The results of this work can be utilized to optimize the cylinder block anti-overturning behavior and outlet ripple suppression of the axial piston pump, as well as to improve the control performance of the EHA.
What problem does this paper attempt to address?