Synchronization Process Analysis of Line Start Permanent Magnet Synchronous Machine

Junli Huang,Shanming Wang,Wenmao Liu
DOI: https://doi.org/10.1109/icem60801.2024.10700227
2024-01-01
Abstract:Ahstract-Line-start permanent magnet synchronous machines (LSPMSM) can start without converters, enabling them to replace asynchronous machines in low-cost industrial applications. The starting process of line-start interior permanent magnet synchronous machine(LS-IPMSM) still lacks accurate analysis. In this paper, we use the quasi-static method to simplify the five-rank dq0 model to a two-rank model. A new method is proposed to compute the synchronous capability of LSPMSMs based on the simplified model. Simulation results show the high accuracy of the simplified model during the starting process and the effectiveness of the proposed method to compute the starting capability for LS-IPMSMs compared to the conventional method.
What problem does this paper attempt to address?