Simultaneous Measurement of Strain and Temperature Based on PDMS Sealed NCF Offset Sensor

Jia Liu,Xianchao Yang,Zhongyang Li,Yuhuai Liu,Jianquan Yao
DOI: https://doi.org/10.1016/j.yofte.2024.103983
IF: 2.8
2024-01-01
Optical Fiber Technology
Abstract:An optical fiber Mach-Zehnder interferometer (MZI) is designed and demonstrated for the simultaneous measurement of strain and temperature. One microcavity fabricated by no-core-fiber (NCF) offset splicing is used to generate two different light paths for MZI, then sealed with polydimethylsiloxane (PDMS) to enhance the strain and temperature sensing ability. The strain and temperature sensing characteristics were simulated theoretically and investigated experimentally. The maximum strain sensitivity of -16.3 pm/mu epsilon was obtained in the range of 0-500 mu epsilon, and the ultrahigh temperature sensitivity of 10.45 nm/degree celsius was obtained in the range of 20-40 degrees C. The influence of microcavity length was analyzed in detail and the dual-parameter demodulation was demonstrated by solving a two-dimensional sensing matrix. The designed sensor with the merits of simple structure, easy fabrication and highly sensitive to weak strain and temperature, make it of great potential for the structural safety monitoring or wearable strain and temperature detections.
What problem does this paper attempt to address?