Abstract:The complex and unstable thermodynamic equilibrium of phosphoric acid wastewater (PAWW) has posed big challenges to conventional phosphorus (P) recovery methods via chemical precipitation process. This study proposes a tailored P recovery strategy from PAWW based on a dual-module flow electrode capacitive deionization (FCDI) system, which includes a P recovery module and a desalination module. The dual-module FCDI system efficiently separates P from impurities in simulated PAWW, through unique flow electrode circulations. And it demonstrates reasonable electrical energy consumption for P recovery of 2.45 kWh/kg P (constant voltage of 1.2 V). Over a continuous operation of the dual-module FCDI system for approximately 26.5 h, a P-enriched solution (8298 mg P/L) is successfully recovered from simulated PAWW, and then high-purity vivianite (Fe3(PO4)2 3 (PO 4 ) 2 8H2O) 2 O) product is synthesized. The P recovery efficiency of the whole process reaches 78.66 %. This study provides an environmentally friendly strategy to recover P from PAWW based on FCDI technology.