Abstract:Solar control films (SCFs) have been widely studied as energy-saving retrofitting for buildings. To investigate the cooling effect of SCFs, a series of reduced-scale outdoor experiments were conducted to analyse the cooling effects of different kinds and orientations of SCFs and the joint effect of SCFs and cool materials. The impact of various weather conditions and nighttime use of SCFs on indoor air temperature was also discussed. It was found that the unidirectional fluoroscopy grey film (UFF-G) had the best cooling effect, reducing indoor air temperature by up to 4 degree celsius. The maximum temperature difference in indoor air caused by SCFs on different orientations can reach 4.8 degrees C, with west or south-facing SCFs resulting in lower indoor temperatures. Additionally, using both SCFs and cool materials can result in a maximum temperature decrease of 4.5 degrees C compared to using SCF alone. The cooling effect of SCFs could decrease on overcast and rainy days, and buildings without SCFs have lower indoor air temperatures at night. Our experimental results can offer theoretical references for energy-saving renovation of glazing systems with SCFs, creating a more comfortable indoor thermal environment and energy-efficient buildings.