Multi-Capacitor Cascaded Absolute Time-Grating Angular Displacement Sensor

Zhicheng Yu,Yanmei Guo,Xiaokang Liu,Hongji Pu,Kai Peng
DOI: https://doi.org/10.1109/jsen.2024.3422504
IF: 4.3
2024-01-01
IEEE Sensors Journal
Abstract:This paper proposes a high-precision absolute time-grating angular displacement sensor with a cascade structure consisting of a double stator and a single rotor. The bottom stator of the sensor is coupled with the bottom side of the rotor to generate coarse and fine induction signals, and the top side of the rotor receives induction signals through the internal leads of the rotor. These signals electrically couple with the top stator to achieve a cascade of signals, thus avoiding the rotor leads. The sensor also utilizes a combination of fine and coarse measurement sections to achieve absolute positioning. A prototype sensor with outer diameter Φ=100 mm and inner diameter Φ=50 mm was fabricated using standard PCB processes, and the experimental analysis found that the fine and coarse measurement parts generated signal crosstalk with each other, resulting in large measurement errors. Frequency domain analysis revealed the error was contained primarily in the first harmonic component of the error signal. To mitigate the crosstalk, we implemented time-division in the excitation signals and structurally optimized the transmitter and receiver rings to use a multiplexing method. This approach significantly reduced crosstalk and increased the signal coupling area of the rotor and stator. The final experimental results showed an accuracy of ± 2.83″ over the entire circumference for the optimized sensor.
What problem does this paper attempt to address?