Abstract:A cold energy utilization scheme for dual-energy heavy-duty trucks (DHDTs) using liquid hydrogen (LH2) and liquefied natural gas (LNG) was proposed to reduce the evaporation loss of cryogenic fuel and enhance dormancy. High-performance thermal insulation of LH2 and LNG tanks is realized by combinatorial design of LNG cooled shield (LNGCS), LH2 cooled shield (LHCS) and multi-layer insulation (MLI). A thermodynamic model is established to optimize the positioning of LNGCS and LHCS within MLI system, and the impact of pressure and flow rate on heat leakage is analyzed, the reliability and environmental benefits of the cold energy utilization scheme is demonstrated for LNG and LH2 DHDTs. The results showed that LHCS can eliminate heat flux entering the LNG tank through MLI, and the optimal position for LNGCS within MLI was determined to be 75%. The heat absorption of LNGCS and LHCS was found to be inversely proportional to pressure and directly proportional to flow rate. In contrast to tanks without cooled shields, the daily evaporation rates of LNG and LH2 tanks decrease by 60.2% and 26.8% respectively. Moreover, LNGCS and LHCS significantly improved the dormancy of LNG and LH2 tanks.