Abstract:Safe and stable operation is the key concern of the current research on the inductive pulsed power supply (IPPS). Although the energy storage density of the IPPS is higher than that of the capacitive pulsed power supply (CPPS), the mutual influence between different modules when they are discharged asynchronously might degrade the performance and cause a fault in IPPS. Therefore, the crosstalk interference needs to be analyzed, which can provide a basis for the IPPS system design. This article establishes a circuit model, deduces the formula for estimating the crosstalk current, and proposes some indicators to measure its influence on the module. Furthermore, a conservative method for judging whether the multimodule IPPS system can operate safely and stably when it discharges asynchronously is put forward. Several cases are selected for simulation, and the results show that crosstalk interference may cause the output current of modules to decrease and the thyristor withstands voltage to increase. Besides, the influences of the crosstalk interference obtained by the simulation are both smaller than those obtained by the judgment method proposed in this article, which indicates that the circuit model is correct and the method is effective. With this method, the parameter design of the thyristor withstands voltage and the module output current can be further carried out.