Performance assessment of a two-stage evaporation grade compression heat pump system for double temperature level drinking water production
Yingying Tan,Zhaoning Hou,Lin Wang,Xiuzhen Li,Zhanwei Wang,Junfei Yuan
DOI: https://doi.org/10.1016/j.applthermaleng.2023.120488
IF: 6.4
2023-06-01
Applied Thermal Engineering
Abstract:The heat pump is widely used for space and water heating, but it has problems of low heating efficiency and inadequate heating at a large temperature span. According to the concept of energy cascade utilization and production, a two-stage evaporation grade compression heat pump (TE-GCHP) system is proposed in this paper for double temperature level boiled drinking water production. In this novel system, the application of grade compression matching multistage evaporation process realizes cascade utilization of the low grade thermal energy and cascade production of the hot drinking water, i.e. the refrigerant vapor from the intermediate-temperature water-cooling evaporator is sucked into the intermediate pressure suction port of the compressor to undergo the compression process of low compression ratio, while the refrigerant vapor from the low-temperature air-cooling evaporator is sucked into the low pressure suction port of the compressor to undergo the compression process of high compression ratio, so as to improve heating performance of the TE-GCHP system at large temperature spans. The energetic and exergetic analysis methods are used to evaluate heating performance of the proposed system and comparisons with the conventional waste heat-recovery single-stage compression heat pump (WH-SCHP) system are also discussed. The results indicate that there are the optimum water inlet temperature of medium-temperature water chamber and the optimum first-stage compression ratio to obtain the highest COP and exergy efficiency as well as the lowest power consumption, and energy-saving and economic performances of TE-GCHP system are markedly superior to those of WH-SCHP system and electric boiler. At evaporating temperature in the range of −10 °C to 30 °C, COP of TE-GCHP system is increased by1.06~1.29, and its exergy efficiency is improved by 2.17 %~10.62 %, while exergy loss of TE-GCHP system is reduced by 27.49 % on average, as compared to WH-SCHP system. In addition, as condensing temperature declines from 130 °C to 100 °C, power consumption of TE-GCHP system is decreased by 20.13–35.07 % compared with WH-SCHP system, whereas exergy efficiency of TE-GCHP system is on average 7.99 % higher than that of WH-SCHP system. In addition, the annual costs of the proposed system are 53.20 % and 69.68 % lower than those of the WH-SCHP system and electric boiler respectively.
energy & fuels,engineering, mechanical,thermodynamics,mechanics