Abstract:Coherent Raman scattering spectroscopies have been established as a powerful tool for investigating molecular systems with high chemical specificity. The existing coherent Raman scattering techniques detect only Raman active modes, which are a part of the whole molecular vibrations. Here, we report the first observation of coherent anti-Stokes hyper-Raman scattering (CAHRS) spectroscopy, which allows measuring hyper-Raman active vibrations at high speed. The CAHRS process relies on a fifth-order nonlinear process that combines hyper-Raman scattering with coherent Raman scattering. Observed signals are proven to come from the CAHRS process through various experiments concerning the dependences of the signals on incident laser powers, time-delay, polarizations, and selection rules of molecular vibrations. Comparisons of CAHRS signals with spontaneous hyper-Raman signals from para-nitroaniline solutions and benzene liquid manifest much higher signal-to-noise ratios of CAHRS signals than spontaneous hyper-Raman signals. This study illustrates that CAHRS spectroscopy can offer new information on molecular vibrations unobtainable from the present coherent Raman techniques at a much higher speed than spontaneous hyper-Raman spectroscopy.
What problem does this paper attempt to address?
The main problem that this paper attempts to solve is to develop a new coherent Raman scattering technique - Coherent Anti - Stokes Hyper - Raman Scattering (CAHRS) spectroscopic technique, in order to achieve high - speed measurement of molecular vibration modes, especially those hyper - Raman - active vibration modes that cannot be detected in conventional Raman spectroscopy.
### Specific problems and goals:
1. **Improve signal intensity and measurement speed**:
- Existing coherent Raman scattering techniques (such as CARS and SRS) mainly detect Raman - active modes, which account for only a part of molecular vibrations. Hyper - Raman Scattering (HRS) can detect more vibration modes, but because its signal is very weak, it leads to a long measurement time and is difficult to be widely applied.
- The CAHRS technique significantly improves the intensity of the hyper - Raman signal and the measurement speed by utilizing the fifth - order nonlinear process and combining hyper - Raman scattering and coherent Raman scattering.
2. **Obtain new molecular vibration information**:
- Conventional Raman spectroscopy and infrared spectroscopy have specific selection rules, and some vibration modes are "silent" in these techniques (i.e., neither Raman - active nor infrared - active). The CAHRS technique can detect these "silent modes" and provide new molecular vibration information.
- By comparing the CAHRS signal with the spontaneous hyper - Raman signal, the research found that the CAHRS signal has a higher signal - to - noise ratio, so it can obtain molecular structure and dynamics information more accurately.
3. **Verify the effectiveness and reliability of the technique**:
- Through a series of experiments, such as laser power dependence, time delay, polarization characteristics and selection rules, it is verified that the observed signal does indeed come from the CAHRS process.
- The experimental results show that the CAHRS technique can provide high - resolution molecular vibration information in a short time and is not affected by non - resonant background signals.
### Technical principles:
- **Energy diagram**:
- The CAHRS process is based on six - wave mixing. When \(2\omega_1-\omega_2\) matches the frequency of the hyper - Raman - active vibration mode, vibration coherence will be generated.
- The polarization of the CAHRS signal is expressed as:
\[
P_{\text{CAHRS},i}^{(5)}=\chi_{ijklmn}^{(5)}(4\omega_1 - \omega_2;\omega_1,\omega_1,\omega_1,\omega_1,-\omega_2)E_j(\omega_1)E_k(\omega_1)E_l(\omega_1)E_m(\omega_1)E_n^*(\omega_2)
\]
- Here, \(\chi^{(5)}\) is the fifth - order nonlinear susceptibility, and \(E(\omega_1)\) and \(E(\omega_2)\) are the electric fields of the \(\omega_1\) and \(\omega_2\) lasers respectively.
- **Phase - matching conditions**:
- The phase - matching condition for the CAHRS signal is \(k_{\text{CAHRS}} = 4k_1 - k_2\), while the phase - matching condition for the CARS signal is \(k_{\text{CARS}} = 2k_1 - k_2\).
### Experimental results:
- **Signal detection**:
- The CAHRS signal in the p - nitroaniline (PNA) solution was observed through experiments, and the signal intensity was significantly higher than the non - resonant background signal.
- Through experiments with different time delays, laser powers and polarization combinations, the characteristics and sources of the CAHRS signal were further verified.
- **Application prospects**:
- The CAHRS technique can not only detect vibration modes that cannot be detected in conventional Raman spectroscopy, but also can provide high - resolution molecular vibration information in a short time, and is expected to play an important role in molecular imaging and ultrafast dynamics research.
In conclusion, this paper solves the limitations of existing Raman spectroscopy techniques in detecting hyper - Raman - active vibration modes by developing and verifying the CAHRS technique, for molecules.