Design Characteristics Analysis of RTVO for a Nuclear Power Plant

Hongyan Tian,Ming Li,Yu Zheng
DOI: https://doi.org/10.1117/12.3017726
2024-01-01
Abstract:An passive nuclear power plant uses the start-up feed water system as the secondary heat sink of defense in depth function. When losing main feed water, the RTVO (Reactor Trip Valve Override) logic automatically trips the steam turbine and opens the start-up feed water regulating valve (SFCV) to remove core heat and to prevent the actuation of the safety-related passive residual heat removal system (PRHR). On October, 2018, the nuclear power plant lost its main feed water supply, RTVO actuated, PRHR actuated and safeguards actuation signal (“S” signal) actuated. Based on the evolution of this accident, this paper analyzes the design characteristics of RTVO and puts forward some suggestions for improvement.