Experimental Study on the Interfacial Bond Behavior Between Cfrp and Concrete Using the Hybrid Bonding Technique

Chao Jiang,Wen Xiong,Yixiao Fu,Jianshu Ye
DOI: https://doi.org/10.1016/j.conbuildmat.2024.135477
IF: 7.4
2024-01-01
Construction and Building Materials
Abstract:Fiber reinforced polymer (FRP) has been widely used as a strengthening material for structures. Hybrid bonding (HB) technique is developed to effectively prevent the FRP debonding in applications. However, researches on the bond behavior with this technique is limited. This study aims to investigate the bond behavior between CFRP and concrete after the HB strengthening. Double shear test was conducted on eight specimens with concrete blocks, CFRP strips, and anchorage. Effects of the bond length and number of plies were considered in the test. Results showed that FRP rupture is the primary failure mode for the CFRP-concrete interface with the HB technique, and anchorage failure will also occur if the shear load at the steel plates is larger than the pull out load of the anchorage. The recommended pull out load of a single anchor set for the HB technique is 14.5 kN. Failure process of the CFRP-concrete interface with HB technique is divided into three stages and the increase of number of plies of CFRP strip effectively increases the load in the third stage. To fully utilize the bond strength of the externally bonded CFRP strip, a recommended spacing of the anchorages is in the range of 0.6Le to 1.0 Le. Bond strength of the CFRP-concrete interface with HB technique can be well predicted by the proposed models under different bond lengths.
What problem does this paper attempt to address?