Research on a Long-Pulse High-Power 170GHz Gyrotron

Bentian Liu,Bo Chen,Jixiang Liu,Xiaojie Wang,Huaichuan Hu,Fukun Liu
DOI: https://doi.org/10.1109/CSRSWTC60855.2023.10427418
2023-01-01
Abstract:The MW gyrotrons are key devices in ECRH of magnetic confinement nuclear fusion systems. In order to achieve the high-power and long-pulse of the gyrotron, which will be adopted in the CFETR, a <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\mathbf{TE}_{\mathbf{25}.\mathbf{10}}-\mathbf{mode}$</tex> 170GHz gyrotron research are given in this paper. A single-anode magnetron injection gun (MIG) and the cylindrical resonant cavity operating at the <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\mathbf{TE}_{\mathbf{25}.\mathbf{10}}-\mathbf{mode}$</tex> are designed and optimized by PIC. The theoretical output power of the gyrotron with operating Voltage 75 kV, electron current 45 A is about 1.1 MW, corresponding to electron efficiency of 32.6%. The prototype of the gyrotron with the mode convertor and single-depressed collector has been fabricated and tested preliminarily. The experimental results of the 170 GHz gyrotron are that an output power of ~520 kW with Gaussian beam has been achieved at 200-ms pulse length in operating voltage 53.3 kV, electron beam 32 A.