Endoscopic Removal of Esophageal Foreign Body Embedded in Muscularis Propria.

Lingzhi Qin,Haitao Shi,Xue Zhang,Peiqi Chen,Xin Liu,Jinhai Wang,Bin Qin
DOI: https://doi.org/10.1055/a-2239-3296
2024-01-01
Endoscopy
Abstract:A 53-year-old man presented with a 3-week history of retrosternal pain after the ingestion of hard food. A computed tomography (CT) scan of the chest indicated a transverse high-density opacity in the middle of the esophagus, extending into the right mediastinum. Esophagoscopy showed edema of the mucosa and granulation tissue at the right posterior esophageal wall 31 cm from the incisors, surface erosion with a small amount of purulent discharge, and no foreign body found in the lumen. Ultrasonography suggested a hyperechoic area in the right posterior muscularis propria layer of the esophagus, connected to a hypoechoic lesion outside the esophagus ([Fig. 1] a); imaging indicated an entirely embedded esophagus-penetrating foreign body and mediastinal abscess. A routine chest and enhanced CT scan revealed a high-density line, 22.9 mm in length, embedded in the middle esophagus and protruding into the mediastinum, with uneven soft tissue enhancement ([Fig. 1] b). No vascular injury was detected.
What problem does this paper attempt to address?