Frequency Stabilized Transverse Zeeman Laser Interferometric Measuring System with Thermoelectric Cooler

Linzhi Wu
2008-01-01
Abstract:The technology of magnetic field set up, signal acquisition, frequency stabilization with thermoelectric cooler (TEC) using master and slave control loop of transverse Zeeman He-Ne laser is introduced. The interference subdivision electronics composed of programmable frequency multiplier module and dual-channel continuous buffer counter module is presented, which may be set to acquire four pulse count subdivision factors of 2, 4, 6 and 16 by using buttons, which means four different measuring resolutions. Experiment results show that the frequency stability of the frequency stabilized transverse Zeeman He-Ne laser is 1.74×10-9, the temperature of the laser tube is 43 ℃. This laser avoids both the shortcomings of high temperature produced by heating stabilization method and the low short term stability of fan cool method. The interferometer has four measurement resolution, they are 0.16 μm, 0.08 μm, 0.04 μm and 0.02 μm respectively.
What problem does this paper attempt to address?