Microleakage Evaluation of the Use of Different Bonding Agents Before Fissure Sealing

Yin Su
2009-01-01
Abstract:Objective To evaluate the microleakage and internal seal of using different bonding adhesives before fissure sealant.Methods Sixty-five caries-free upper premolar teeth were randomly divided into five groups.Group 1 was sealed with fissure sealant after phosphoric acid etching.Group 2 received Prime Bond NT before fissure sealing without saliva contamination.Group 3 was sealed with a self-etching adhesive(Clearifil SE Bond)without prior etching.Group 4 was slightly moistured with saliva before sealant application.Group 5 was slightly moistured with saliva,then applied with Prime Bond NT before fissure sealing.After thermo-cycling,10 teeth of each group were immersed in 1% methylene blue solution for 72 hours.The teeth were sectioned for evaluation of microleakage.Three teeth of each group were analyzed by SEM for internal adaptation of the fissure sealants.Results Fissure sealants in Group 3 and 4 showed more microleakage and less sufficient internal seal compared with sealants placed in Group 1,2and 5.Group 2 leaked significantly less than the other four groups.Conclusion The total-etching adhesive Prime Bond NT can improve sealing ability with regard to better internal adaptation of the sealants.The self-etching bonding agent Clearfil SE Bond does not improve fissure sealing and is not recommended for fissure sealing.