A Contrast Study of Low-temperature Waste Heat Utilization Modes for a 5000 T/d Class Cement Kiln

Yiping Dai
2009-01-01
Abstract:To more effectively utilize low temperature waste heat and reduce the energy consumption of a cement kiln,an exploratory study was conducted of the low-temperature waste heat utilization modes for power generation in a 5 000 t/d class new type dry-method cement kiln.With the exhaust gas extracted from a cooler in the front portion of the kiln and a preheater in its tail portion serving as a heat source,the models of single-pressure,dual-pressure and flash circulation system were established.By using genetic algorithms,optimized were the thermodynamic characteristic parameters for various cycles.The dual-pressure system configuration was improved with the respective merits and demerits of the single-pressure,dual-pressure and flash system being compared.The analytic results show that the improved dual-pressure circulation system has a maximum power output and the flash system,however,is simple in structure and flexible in operating modes.Both systems feature relatively wide applications.
What problem does this paper attempt to address?